Institutional-Repository, University of Moratuwa.  

Development of organ stiffness models for haptic feedback in laparoscopic surgery simulation

Show simple item record

dc.contributor.advisor Dayananda, NWN
dc.contributor.advisor Kumarage, S
dc.contributor.author Kannangara, SM
dc.date.accessioned 2019-04-10T01:52:49Z
dc.date.available 2019-04-10T01:52:49Z
dc.identifier.citation Kannangara, S.M. (2018). Development of organ stiffness models for haptic feedback in laparoscopic surgery simulation [Master’s theses, University of Moratuwa]. Institutional Repository University of Moratuwa. http://dl.lib.mrt.ac.lk/handle/123/14184
dc.identifier.uri http://dl.lib.mrt.ac.lk/handle/123/14184
dc.description.abstract Laparoscopic surgery is the most common Minimally Invasive Surgery (MIS) performed routinely for certain procedures such as appendectomy and Cholecystectomy. Laparoscopic surgical procedures are very complex compared to open surgeries and require a higher level of experience and expertise. A comprehensive training session on surgical simulator handling for trainee surgeons is highly recommended before the hands-on training in a real surgery. Comprehensive surgery simulators such as physical phantoms which are available for training are expensive and not readily available in many health care centers around the world. VR simulators have a great potential to revalorize the training paradigm of surgical interns. The haptic feedback plays as equally as visual feedback to provide a realistic environment to trainees. Realistic organ-force model is a key requirement of a VR simulator to experience real-time tool-tissue interaction forces. However, modeling real tissue properties has not been achieved due to several limitations such as the inaccessibility to in-vivo tissue properties, the complex behavior of biological tissues and anatomical variability. We have adopted an alternative approach to incorporate force feedback to VR simulators. The abdomen organ models (liver, gallbladder, stomach, bone, and vessel) were generated using the color Cryosection dataset of the Visible Human Project. A novel method was applied to render forces by fine-tuning the stiffness of organ model and integrating the three force ranges: soft, mild/firm and hard into organ models using feedback received from expert surgeons. The proposed system provides the interaction forces through a haptic device with six Degrees of Freedom (DoF) position sensing and three DOF force feedback. The simulated organ models were evaluated by two experienced surgeons. The proposed haptic models were mostly in harmony with their experience in real-world tool-tissue interaction and the overall accuracy of identifying the correct organ property was more than 68%. The organ models were also tested with senior registrars. The results showed a considerable improvement amounting to more than 34% chances of selecting the correct organ property after training. en_US
dc.language.iso en en_US
dc.subject ELECTRONICS AND TELECOMMUNICATION ENGINEERING-Thesis en_US
dc.subject PHILOSOPHY-Thesis en_US
dc.subject LAPAROSCOPIC SURGERY en_US
dc.subject MINIMALLY INVASIVE SURGERY(MIS) en_US
dc.subject VIRTUAL REALITY SIMULATORS(VR) en_US
dc.subject HAPTIC FEEDBACK
dc.title Development of organ stiffness models for haptic feedback in laparoscopic surgery simulation en_US
dc.type Thesis-Full-text en_US
dc.identifier.faculty Engineering en_US
dc.identifier.degree Master of Philosophy en_US
dc.identifier.department Department of Electronic and Telecommunication Engineering en_US
dc.date.accept 2018-07
dc.identifier.accno TH3640 en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record