dc.description.abstract Analysis of Vibration Levels at Nearby Structures Due to Road Construction Activities The purpose of this research is to analysis of vibration levels at nearby structures due to road construction activities. Vibration caused various types of structural damages and it may finally affect the project progress. Although, there are systems to control these issues, it is reported that available systems are not reliable, effective and systematic. Even though, there are many research studies about quantitative vibration studies, nobody presented systematic holistic solution for these problems. Main Objectives of this research is propose a vibration management plan prior to the start of construction and evaluate current vibration standards of Sri Lanka and propose suggestion to improvements. Firstly, existing vibration and structure damage monitoring systems of Sri Lanka and other countries were studied. Secondly data regarding existing system from experience site and Highway engineers were collected. Finally, vibration was monitored when do major vibration generation road construction activities which used heavy vibrator rollers. Damages due to vibration depends on structure type, vibration value and affected time period. Those factors are taken into account to establish a vibration management plan. This vibration management plan will provide fair solution to both parties who take vibration consequences in construction and contractors. For the survey, hilly terrain area road section with various subgrade conditions is used. On the basis of the results of this research, it can be concluded that vibration limits are exceeded its damage limits in nearby structure and current boundary limits are not in optimum range and it should change with structure condition and subgrade strength. Furthermore, Sri Lanka standard of vibration limits for construction vibration should be revised after proper analyze. According to this research analyze Type 1, Type2 and Type 3 structures prescribed limits easily can be increased up to higher limits. It will be helpful to contractor to do undisturbed work without contradicting government rules and regulation. As a result, sustainability of the road project can be improved. According to questionnaire survey 84 % engineers think existing system should improve to meet sustainable road development and 85% engineers think vibration monitoring system is required for construction activities. en_US
dc.language.iso en en_US
dc.subject Vibration en_US
dc.subject Compaction en_US
dc.subject Structure en_US
dc.title Analysis of vibration levels at nearby structures due to road construction activities en_US
dc.type Thesis-Full-text en_US
dc.identifier.faculty Engineering en_US
dc.identifier.degree Master of Engineering in Highway & Traffic Engineering en_US
dc.identifier.department Department of Civil Engineering en_US
dc.date.accept 2017-06