DEVELOPMENT OF A SPEED STABILIZER FOR RAPID SYNCHRONIZATION OF MINI-HYDRO GENERATOR A dissertation submitted to the Department of Electrical Engineering, University of Moratuwa in partial fulfillment of the requirements for the Degree of Master of Science by D.G. Subasinghe Supervised by Dr. J.P. Karunadasa i_ldHAn . ... . i or l . i j i i A > S f t l ' MORATUWA Department of Electrical Engineering University of Moratuwa, Sri Lanka January 2009 University of Moratuwa TW 92960 92960 9 2 C 6 0 DECLARATION The work submitted in this dissertation is the result of my own investigation, except where otherwise stated. It has not already been accepted for any degree, and is also not being I endorse the declaration by the candidate. Dr. J.P. Karunadasa i 1 it. • ** • • 4*J v jw. y i ABSTRACT The objective of this study is to develop a damping method to stabilize the speed of the generator rotor during synchronization so as to minimize synchronization time and also to develop a prototype circuitry for a selected Mini-Hydro plant to obtain actual results. The present system of the identified Mini-Hydro generator was modeled reasonably to identify the present response of the system for a step input. This was then simulated in Matlab and based on that a new PI controller with a power electronic switching circuit was developed to impart a resistive loading to generator in order to control the oscillation of the rotor during synchronization. Two switching strategies are discussed and they were tested at site for actual results. One of the switching strategies showed positive results where the controller's performance is mostly in line with the simulated results. ii ACKNOWLEDGEMENT First I pay my sincere gratitude to Dr. J.P. Karunadasa who encouraged and guided me to conduct this research and on perpetration of final dissertation. I make this opportunity to extend my thanks to Dr. Narenda De Silva for the valuable instructions given to me during the project. I would like to take this opportunity to extend my sincere thanks to Mr. Prabath Wickramasinghe (Head-Industrial Solutions - Hayleys Ltd), Mr. Sudharshana Gamage (Electrical Engineer - Hayleys Ltd), Mr. M.G.K. Jayathunga (Superintendent - Gomala Oya (Pvt) Ltd) and his staff, Mr. D.U. Jayasooriya (Electrical Engineer - Ceylon Electricity Board) and his staff, Mr. A. Weerarathne (Electrical Engineer - Orient Electric (Pvt) Ltd), Nalaka Samarakoon (Executive- Orient Electric (Pvt) Ltd), W.A. Wijesiri (Electrical Engineer - Colombo Dockyard Ltd), R. Ranasinghe (General Manager - Orient Mag Line (Pvt) Ltd) and his staff, P.B.S.K. Baduwasam (Electrical Engineer - Micro Cells Ltd), who gave their co-operation to conduct the research and to develop the Prototype design successfully. It is a great pleasure to remember the kind cooperation extended by the colleagues in the post graduate programme, friends, my subordinates in the office and especially my wife who helped me to continue the studies from start to end. Finally, I should also admire the patience of my beloved two kids during the project. CONTENTS Page No. Declaration i Abstract ii Acknowledgement iii Contents iv - vi List of Tables vii List of Figures vii - viii Chapter 1- Introduction 1 - 5 1.1 Background 1.2 Hydro Electric Plant Schemes 1.3 Frequency of shutdowns of a Mini-Hydro Generator 1.4 Synchronizing of a Mini-Hydro Generator with the Grid 1.4.1 Ramping Period 1.4.2 Synchronizing Period 1.4.2.1 Downtime during Synchronization Period 1.4.2.2 Loss of Energy Production during Synchronizing Period 1.4.3 Importance of Minimizing the Synchronization Period 1.4.4 Impact on the Present Design of the Plant 1.5 Motivation Chapter 2 - Problem statement 6 - 7 2.1 Identification of the Problem 2.2. Objective of the Project 2.3 Importance of the Project Chapter 3 - System Modeling 8 - 2 2 3.1 Introduction 3.1.1 Details of Identified Mini-Hydro plant 3.1.2 Initial Field Measurements 3.2. Notation 3.3. Model of the Present Mini-Hydro Generator 3.3.1 Torque Equilibrium 3.3.2 Power Equilibrium 3.3.3 Laplase Transformation of Power Equilibrium 3.3.4 Governor Model 3.3.5 Turbine Model 3.4. Model of the Present Mini-Hydro Generator during Synchronization. 3.4.1 Estimation of Model Parameters during Synchronization. iv 3.4.2 Estimation of value for C 3.4.3 Estimation of Pm 3.4.4 Matlab Program to Estimate K, a & b 3.5. Model of the Mini-Hydro Generator when 'Artificial Load' is connected during Synchronization. 3.5.1 New controller to control the switching of Artificial Load 3.5.2 Matlab Program to Estimate Kp, d Chapter 4 - Switching Circuit 2 3 - 3 3 4.1. Switching of Artificial load 4.1.1 AC Power Supply from Generator Switchgear 4.1.2 The Resistive Load Bank 4.1.3 3 Phase Full Wave Diode Rectifier 4.1.4 IGBT Gate Driver Circuit 4.1.5 Speed Sensing Circuit 4.2. Installation of Prototype Circuit Module at site 4.2.1 Termination of load Bank Power Cables Chapter 5 - Switching Strategy 3 4 - 3 8 5.1. Introduction 5.1.1 Switching Strategy 5.1.2 Strategy -{I) Synchronization begins with Artificial Load ON state 5.1.3 Strategy -(II) Synchronization begins with Artificial Load OFF state and agricultural activities 5.2 Observation of Simulation results Chapter 6 - Programming of Microprocessor 3 9 - 4 5 6.1. Continuous to Discrete conversion of PI Controller 6.2. Comparison of simulation results for Continuous PI and Discrete PI controllers. 6.3. Selection of Microcontroller unit (MCU) 6.3.1 Speed Error detection by Micro Processor 6.3.2 PI Algorithm implementation 6.3.3 Generate Duty Factor of PWM in proportional to PI control signal. 6.4. Programming of Microprocessor 6.5. Outline to preliminary Testing of Circuitry. 6.6. Installation of the sub-components of the circuit Chapter 7 - Experimental Results and Conclusion 4 6 - 4 9 7.1. Testing at Site 7.2 Experimental Results with Switching Strategy I 7.3 Experimental Results with Switching Strategy II 7.4 Conclusion References Appendix I Appendix II Appendix III Appendix IV Appendix V Appendix VI Appendix VII vi List of tables Table number Description Table 1.0 Present status of the Mini-Hydro Projects in Sri Lanka. Table 1.1 Details of number of Shutdowns of selected Mini-Hydro plant. Table 4.1 Truth Table of 4 input NAND gate with Hysteresis. Table 5.1 Simulation of switching strategy I & II. List of figures Figure number Description Figure 1.0 Graph of a typical Generator speed Vs Time during Synchronization. Figure 3.0 'Gomala Oya' Mini-Hydro Plant at Ehelliyagoda. Figure 3.1 Graph of Frequency Vs time during Synchronization. Figure 3.2 A Picture of Governor, Francis Turbine and Generator. Figure 3.3 A picture of Hydraulic Governor (shown in color Blue). Figure 3.4 A picture of Francis Turbine with 12 Wicket Gates. Figure 3.5 Model of the present Mini-Hydro Generator. Figure 3.6 Model of the present Mini-Hydro Generator during synchronization. Figure 3.7 A picture of the Automatic Synchronizer of the plant. Figure 3.8 Rotor Speed Vs Time when rotor spinning freely. Figure 3.9 Unit-Step response of present Mini-Hydro Generator. Figure 3.10 Model of Mini-Hydro Generator with 'Artificial Load' during synchronization. Figure 3.11 Unit-Step response of the Mini-Hydro Generator when Artificial load is connected. Figure 4.1 Line Diagram of the Switching Circuit. Figure 4.2 Circuit of the DC Load Bank. vii Figure 4.3 A picture of the load bank, connected through a 30A/ 4P MCB Figure 4.4 3 Phase Full Wave Diode Rectifier Circuit. Figure 4.5 DC waveform with Voltage Ripple after rectification Figure 4.6 A picture of 3 Phase Rectifier Figure 4.7 Summery of semi conductor device capabilities. Source: Ned Mohan [6]. Figure 4.8 An IGBT: (a) Symbol, (b) i-v characteristics (c) idealized characteristics. Source: Ned Mohan [6]. Figure 4.9 PWM Output and Gate Signal to IGBT. Figure 4.10 IGBT Gate Driver Circuit. Figure 4.11 A picture of the IGBT mounted on a Heat Sink. Figure 4.12 A picture of PIC 16F877A Microprocessor based driver circuit. Figure 4.13 Diagram of Speed Sensing Circuit. Figure 4.14 Pin details of SN7413 Schmitt Trigger. Figure 4.15 A picture of Speed Sensing circuit Figure 4.16 Square wave signal output from Schmitt Trigger, converted from Sinusoidal voltage sources. Figure 4.17 A picture after connecting Load Bank cables at Generator terminals Figure 5.1 Model of the system with Switching Strategy I. Figure 5.2 Results of simulation with Switching strategy I. Figure 5.3 Model of the system with Switching Strategy II. Figure 5.4 Results of simulation with Switching strategy II. Figure 6.1 Model of the. system with discrete PI controller. Figure 6.2a Results of simulation with Switching strategy I, with discrete PI controller. Figure 6.2b Results of simulation with Switching strategy II, with discrete PI controller. Figure 6.3 Pin details of PIC16F877A microprocessor used for the PI controller. Figure 6.4 A picture during testing, the complete controller circuit mounted inside an IP23 grade panel. Figure 7.1 Frequency Vs Time during synchronization under normal operation. Figure 7.2 Frequency Vs Time during synchronization with switching strategy I. Figure 7.3 Frequency Vs Time during synchronization with switching strategy II. viii